Digital Exit Air Meter

FOAMING CHARACTERISTICS OF LUBRICATING OILS

The Digital Exit Air Meter (DEAM) is a digital air totalizer for use with the Tannas Foam Air Bath (TFAB) or any device for measuring foam characteristics. By totalizing the air used during the 5-minute flow period, the DEAM ensures there are no leaks in the system and verifies the proper volume of air has adequately passed through the Diffuser and into each sample being tested.

 

The use of a device such as the DEAM is required, per ASTM D892, which states, “The total volume of air leaving the foaming test apparatus shall be measured by a volume measuring device capable of measuring gas volumes of about 470 mL.” The only exception is when applying the Alternative Procedure section of the D892 method. Since the method requires an airflow rate of 94 mL ± 5 mL over a 5-minute blowing period, the value reported by the DEAM must be 470 mL ± 25 mL for the test run to conform to the method.

 

ASTM D6082 does not require the use of the DEAM, but states that the use of such a device helps detect leaks. The ASTM D6082 method requires the total volume of air after a test be 1000 mL ± 25 mL since it requires an airflow rate of 200 mL ± 5 mL over a 5-minute blowing period. The DEAM features an LCD display for enhanced readability and ease of use, as well as an in-line filter to ensure the wetted materials of the sensor stay oil free. 

 

Accuracy Value:

±1% of full scale

Voltage Compatibility:

100-240 VAC

Repeatability:

±0.5% of full scale and for units ≥ 100 scm from 0 to 20% of range

Maximum Ambient Temperature:

50°C (122°F)

Minimum Ambient Temperature:

-10°C (14°F)

 

THE PRODUCT

  • Air totalizer
  • For use with any device used to measure foam characteristics
  • Ensuring cylinder and diffuser assembly are free of leaks


THE PURPOSE ACCORDING TO THE METHOD

  • D892 Section 6.3.1 – “The total volume of air leaving the foaming test apparatus shall be measured by a volume measuring device...”
  • D6082 Note 10 – “It is useful to measure the total exit air volume to detect leaks in the system. Refer to D892 for details of apparatus.”


FEATURES

  • LCD display
  • In-line filter
  • Tubing (5 ft, 152.4 cm)
  • Quick Disconnects
  • Hose fitting
  • Power Cord

 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

Country:

This fi.

Digital Exit Air Meter

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.