PSL-Rheotek Pulp​

Pulp

Generating an accurate concentration of pulp and water is a delicate task. Using the iSP-2 helps the operator to achieve an accurate concentration every time. The dispensing of cupriethylendiamine follows after the water shaking has been completed.

 

Pulp sample preparation system PSL-Rheotek

ISP-2  Sample Preparation, supplied complete with precision balance, syringe Pump (s) and voice promting software.

FAST – samples can be prepared in under 75 seconds.

Sample details are automatically transferred to the RPV-1.

Uses weight to weight data rather than weight to volume data to calculate concentration – avoids errors due to temperature/density.

Built in safety checks.

Automatic ASH & MOISTURE corrections to concentration.

Uses AUDIO prompts to talk the operator through the essential preparation steps.

Pre-programmed methods make preparation simple and straightforward.

 

  • Simple & Safe to use
  • Improves accuracy
  • Saves operator time
  • Reduces exposure to hazardous chemicals
  • Standard model suitable for most polymer applications
  • Pulp model complete with two syringe pumps
  • Balance: 4 decimal places
  • Interface: RS232C
  • 2 iSP-1 syringe pumps, 25ml
  • Interface: RS232C

 

Part No. ISP-2

 

FULLY AUTOMATED SAMPLE PREPARATION SYSTEM to make accurate polymer concentrations

 

  • W/W%
  • W/V%
  • Density
  • Ash %
  • Moisture %

 

Complete with…

BALANCE & PUMP

[uses PC on RPV-1]

 

Test Methods

ASTM D1795, SCAN CM15:99, TAPPI T230-OM94

 

The software is updated regularly – taking into account new methods or customer specific requests. Therefore if your method is not mentioned in the above list then please contact us.

 

Advantages

Simple & Safe to use

Improves accuracy

Saves operator time

Reduces exposure to hazardous chemicals

Ensures compliance with test methods

 

Description

Simple Operation

Operator selects one of the pre-programmed methods, types in the sample ID & presses the “Prepare Solution” button. The iSP-1 then takes over and asks the operator for the vial. The iSP-1 uses a series of audio prompts to instruct the operator how to prepare the sample. Safety checks ensure that the vial is placed on the balance. ISP-1 then asks for the sample. The operator adds sample until the iSP-1 prompts them to stop adding sample. Finally the iSP-1 calculates the correct amount of solvent and dispenses it into the vial.

 

Safety

Various safety checks throughout the process ensure the operators safety and prevent solvent being dispensed incorrectly.

 

Automatic Calculations, Results Database & LIMS

Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.

 

Materials of construction & design

The iSP-1 is supplied with a high quality MT balance. The iSP-1 pump is supplied with a tough chemical resistant coating. The pump can be disassembled for easy maintenance.

Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.

 

Typical Applications

  • Pulp, Paper & Microcrystalline Cellulose, according to ASTM D1795 and SCAN CM15:98, TAPPI T230-OM94
  • Nylon according to ASTM D789 [HIGH CONCENTRATION]
  • Nylon according to ISO307[LOW CONCENTRATION]
  • PET according to ASTM D4603
  • PET in OCP [Orthochlorophenol]
  • PET in Phenol/Dichlorobenzene​

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

Country:

This fi.

PSL-Rheotek Pulp

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.