Automatic sample preparation system​

XPREP - A6 & A12

 

Automatic sample preparation system with joint columns for analyzing AOX / TOX

 

Sample preparation of joint columns by analyzing AOX/TOX labor intensive and time consuming?

 

The XPREP-A series is the fastest column method sample preparation system in today’s market. Specially designed to meet international standards like ISO, EPA and DIN methods (e.g. ISO 9562, EPA 9020). It automatically runs 100 mL water samples over the AOX/TOX columns at controlled sample flow of 3mL/min. Once the water sample has passed through the columns a wash cycle automatically starts, which removes the inorganic load from the surface of the activated carbon. The surplus water and wash solution are collected in a central reservoir, which can be connected to a continuous drainage system or simply emptied when it is full. The process is fully controlled by the sample preparation system that can operate as a stand-alone unit.

 

There are 2 basic models to choose from. The XPREP-A12 comes with 2 peristaltic pumps and the XPREP-A6 comes as a single pump configuration. The A12 version supports 12 sample containers and column positions and the A6 offers space for 6 positions. In those configurations, they run 12 or 6 paired columns in full automatic mode, simultaneously. The second column is to assure the breakthrough of sample does not exceed 10% of the total value.

 

Since all channels operate simultaneously, there are some advantages. There is no other AOX column preparation system able to beat these numbers!

 

  • For most AOX coulometric instruments, 6 sample preparation runs with the XPREP-A12, are sufficient to keep the analyzer busy for the next 24 hours.
  • Let’s assume that the average analysis time for sample combustion and titration takes 10 minutes from sample to sample (72 samples = 144 columns = 1440 minutes = 24 hours).
  • 6 Runs with the XPREP-A12 only take about 270 minutes, which means that the sample preparation can easily take place during normal office hours.

 

Combine the XPREP-A series with the TUSCAN column auto sampler for fast, unattended analysis with minimal human intervention and labor time!"

 

Running the analysis, practically unattended, has become the new reality with the TUSCAN column auto sampler. Up to 42 columns can be loaded into the column auto sampler. A full run will take approximately 6-7 hours. While the XPLORER is analyzing, fresh columns can be prepared with the XPREP-A series.

 

With the XPREP-A12 a laboratory can double its sample pre-treatment capacity allowing an even higher sample throughput. This column pre-treatment system is capable of producing enough columns to feed two combustion analyzers on a 24/7 basis.

​

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

Automatic sample preparation system

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.