TLB50 115V-60Hz​

TLB50 115V-60Hz

TLB50 is a thawing bath for sample preparation. The bath has an operating range of -5°C up to +80°C. The benchtop bath with integrated cooling can replace the combination of a water bath with an external cooling circulator. This not only saves bench space, but also costs because of its high cooling efficiency. The TLB50 has a wide bath opening and several options like a fixed or split levelling platform and adjustable rack for placing different sized sample bottles. The primary use of the TLB50 is sample conditioning. Before most samples are analysed, they require to be conditioned to a specified temperature as described in each test method.

 

Bath Temperature Accuracy       

0.02°C

 

Bath Volume     

50 litre

 

Bath Height       

720 mm

 

Weight

65.0000

 

Minimum Temperature

-5°C

 

Maximum Temperature

80°C

 

Details

TLB50 is a thawing bath for sample preparation. The bath has an operating range of -5°C up to +80°C. The benchtop bath with integrated cooling can replace the combination of a water bath with an external cooling circulator.

 

This not only saves bench space, but also costs because of its high cooling efficiency. The TLB50 has a wide bath opening and several options like a fixed or split levelling platform and adjustable rack for placing different sized sample bottles. The primary use of the TLB50 is sample conditioning. Before most samples are analysed, they require to be conditioned to a specified

temperature as described in each test method. Examples are: - ASTM D323 Reid vapour pressure test between 0 to 1°C (32 to 34°F).- ASTM D5 Penetration tests for bitumen. - Long-term storage of gasoline <10°C or <20°C (<50° to 68°F).- ASTM D86 Distillation.

 

The used cooling system is ozone friendly and doesn’t contain any CFK/HCFK gas.

 

The fluid temperature is regulated through an electronic controlled heater and leaving the cooling compressor running continuously. The cooling power is maximized for rapid cooling down of the bath. When the set point temperature is reached cooling power is strongly reduced and it is saving significant energy. In comparison to other standard instruments the TLB50 can save up to 600 Watt of electric energy. Above 40°C cooling is switched-off automatically to save energy.

The temperature readout readout is in two decimals and can be switched between °C or °F via the menu.

 

The bath with stirrer (P/N 00T0071, 00T0072 and 00T0073) uses a vain to stir the bath liquid. A special baffle plate ensures maximum homogeneity. TLB50 with pump (P/N 00T0071, 00T0072, 00T0073) provides circulation in the bath or via an external circuit. The pump offers 7 litres per minute. Maximum pressure is 300 mBar. Connector ¼” or 80 mm hose.

Downloads

 

TLB50 115V-60Hz

Alternative Products

 

A sentence here about related products with image links below to products you want customer to consider. 

SUBMIT

Name:

This field is required.

Thank You for your enquiry.

Your information has been sent successfully.  One of the Crea Laboratory technologies Team will be in contact with your shortly. 

 

If your enquiry is urgent, please call us on 1300 552 725

Email:

This field is required.

Phone:

This field is required.

Industry:

This field is required.

Company Name:

This field is required.

Address:

This field is required.

Post Code:

Country:

This fi.

TLB50 115V-60Hz

For more information on this product or to arrange a call from one of the Cea Petrochemical Team, please complete the contact form below.